The engineering reasoning behind our equipment specifications, application choices, and case studies — source-cited for every technical claim.

Application Guide
10 min read

Aquaphor B510 cartridge selection guide, residual first

Aquaphor B510 carbon-block cartridges for a point-of-use stage: fit depends on which disinfectant residual and form the downstream unit tolerates, so request a quote with format, housing, life and chloramine questions attached.

Read
Application Guide
10 min read

How to read a quote for WaterDoctor SND cultures

WaterDoctor SND cultures for aquaculture water: quotes compare only when each form's concentration unit and dose basis are written. A litre, kilo or tube is not a unit of treatment.

Read
Application Guide
10 min read

Selecting SnowPure Electropure EDI EXL modules

SnowPure Electropure EXL EDI modules polishing RO permeate: a design flow fits only on the RO route and feed it assumes. The sheets print a flow per route beside a feed table, without saying which feed; measure the permeate before sizing.

Read
Application Guide
10 min read

Choosing the Blue-White FLEXFLO A-100N tube first

Blue-White FLEXFLO A-100N for hypochlorite dosing: the tube decides fit. Its flow range at its RPM must cover the site's lowest and peak demand, and its ratings must clear the pump-tube pressure and the chemical.

Read
Application Guide
10 min read

EcoWater ECR3702 selection guide for a household softener

The EcoWater ECR3702 can suit one house when hardness measured at the tap exceeds the guide's 7 gpg screening line, peak flow stays within its printed 11 to 12 gpm rating and the maker confirms a supply for local mains.

Read
Application Guide
10 min read

Screening a feed for Litree LH UF modules

Litree LH UF modules for a pressure UF stage: feed turbidity, temperature and pH fit only against limits Litree confirms in writing; the archived pages read print none. A seller's 12-module figures only screen.

Read
Application Guide
10 min read

Selecting a ProMinent Sigma X from its data table

ProMinent Sigma X hypochlorite dosing turns on one figure: the table's l/h is a minimum capacity at maximum back pressure, for water at 20 °C. A row is a candidate if demand is below it and head, pressure and stroke window allow it.

Read
Application Guide
10 min read

Sizing a Runxin multi-port valve beyond its flow rating

The Runxin F112A3 softener valve prints 40 m³/h, but for RO pretreatment this guide sizes to the tank table's 28.0 t/h at φ1200, a calculation at 25 m/h, once feed limits are met. Hardness, chlorine and inlet pressure come first.

Read
Application Guide
10 min read

Selecting the SEKO Kontrol 800 for a cooling tower

SEKO's Kontrol 800 K800L05 can fit one cooling tower if SEKO confirms a conductivity set-point relay, the make-up conductivity swing stays inside the cycles band and the relays cover the functions; the printed ±2% states no basis.

Read
Application Guide
10 min read

Selecting an SND Container System for aquaculture wastewater

For a WaterDoctor SND Container System on aquaculture wastewater, fit depends on kilograms of nitrogen per day and where it connects; a volume ratio is not a nitrogen capacity.

Read
Application Guide
10 min read

Selecting Atlantium HOD UV Systems for Process Water

Atlantium HOD UV for process water: the flows printed in the documents retrieved are not ratings, so fit rests on dose at the site's UVT and flow, tested against the RZ104 certificate's windows.

Read
Application Guide
10 min read

Sizing a Culligan CTM depth filter for pretreatment

A Culligan CTM depth filter's printed flow holds at a stated rate class and adapter, with the solids load Culligan recommends for each class; measure those first, then check adapter, bed condition and backwash draw.

Read
Application Guide
10 min read

Choosing a ProMinent DULCODES UV line and size

For ProMinent DULCODES UV water disinfection, a table's flow is stated at the basis its footnote prints, and the DULCODES LP prints none. Measure UV transmission first.

Read
Application Guide
10 min read

Selecting the Viqua VH410-F22 for ASEAN point-of-entry

The VH410-F22's printed flow rows assume 95% UVT, and the manual adds end of lamp life and 20 °C; for point-of-entry duty, measure UVT, then size to the lowest printed component rating.

Read
Application Guide
10 min read

Sizing Vontron ULP elements for point-of-use RO

Size Vontron ULP elements for point-of-use RO to the tolerance floor, not the GPD nameplate: it holds only at a bench test line and a tolerance printed on some sheets; measure the feed first.

Read
Application Guide
10 min read

Selecting a Filtersafe Trident E for a high-TSS intake

Whether a Filtersafe Trident E suits a high-TSS intake depends on Filtersafe's written capacity at the buyer's grade and on the buyer's own TSS, pressure and flush-route data.

Read
Application Guide
10 min read

Selecting Amiad Spin Klin disc filters for canal water

Amiad Spin Klin disc filters on open canal water fit first by the back-flush pressure the grade needs at the battery; the pages' flow range does not say what it covers, and one unit's flow and the count are not printed; ask Amiad.