Skip to content
HeroStudio · hero
SEKOITItaly

SEKO Kontrol 800 Multi-Parameter Controller

Multi-parameter water-treatment controller for pH, ORP and conductivity — SEKO's stated example is cooling-tower control.

MarketsSG · MY · ID

Key specifications

Comms
RS485 Modbus RTU
Power
100-240 Vac 50/60 Hz, 15 W
Inputs
pH, ORP, conductivity (three channels, K800L05 build)
Ranges
pH 0–14 ±0.01 · ORP ±2000 mV ±1 mV · Cond 0.054–200,000 μS ±2%
Outputs
Relay outputs: 3 per datasheet description, 6 per its output list — confirm per build · 2× 4-20 mA · 2× frequency
Enclosure
Wall-mount ABS, IP65
ApplicationsCommercialIndustrial
Technical overview

Multi-Parameter Controller — Kontrol 800

The Kontrol 800 is a dedicated multi-parameter controller for complex applications that require a number of chemical parameters to be checked at the same time. It features independent proportional control outputs, two programmable frequency outputs, an RS485 serial port with Modbus protocol, probe quality checking and data logging. The build listed here (K800L05) measures pH, ORP and conductivity.

Outputs & inputs (datasheet)

Clock
Clock module with backup battery
Inputs
Flow (pull-up, Reed sensor input); Hold
Relays
Six, 250 Vac 7 A: four 100–240 V power relays and two dry-contact relays (the datasheet narrative says three relay outputs; its output list says six)
Current outputs
2 channels, 0/4–20 mA, 500 Ω maximum load (precision ±0.01 mA)
Frequency outputs
2 channels, open collector NPN/PNP, 0–120 pulses per minute (precision 0.016 Hz)

Interface & enclosure

Display
4-line display, 20 large white and blue characters
Keyboard
7 keys
Connections
Dual-row connectors
Enclosure dimensions
278 mm (W) × 285 mm (H) × 139.5 mm (D)
Operating environment
0–40°C; relative humidity 0–95% (without condensation)

Functions

Probe life
Probe life statistics tracking (US product page)
Data logging
Data logger function
Probe quality
Probe quality checking (datasheet); electrode quality function (product page)
Relay activation
Multi-method relay activation (product page)

Best for

Cooling-tower control — the application SEKO's product page namesBoiler, reverse osmosis and swimming-pool water treatment (series-level application list in the datasheet)

Key product advantages

  • Reads pH, ORP and conductivity on one controller (K800L05 build)
  • Independent proportional control outputs
  • Two programmable frequency outputs and two 0/4–20 mA current outputs
  • RS485 serial port with Modbus protocol
  • Probe quality checking and data logging
Product story

A closer look

Studio hero of a wall-mount SEKO Kontrol 800 controller — a two-piece light-grey ABS enclosure with a dark navy display bezel printed "seko" (top-left) and "Kontrol 800" (top-right), a blank blue-backlit LCD, a seven-key keypad below the display, and a row of black cable glands along the bottom edge, on a deep blue-teal studio gradient. A compact text block anchored to the top-left carries the headline "Kontrol 800", with "Kontrol" picked out in cyan, and the subtitle "pH · ORP · conductivity, one controller".
Macro close-up of the SEKO Kontrol 800 controller's dark navy display bezel — "seko" and "Kontrol 800" printed above a blank blue-backlit LCD, with the seven-key keypad (left arrow, right arrow, esc/mode, cal, enter, up, down, and a prog bracket) below, against a soft grey studio backdrop. A compact text block anchored to the top-left carries the headline "4-line display", with "4-line" picked out in cyan, and the subtitle "20 characters · 7-key control pad".
The SEKO Kontrol 800 controller wall-mounted under a canopy at a rooftop cooling-tower plant, LCD blank, beside a stainless backplate with two metering pumps whose tubing runs to probe fittings on a grey PVC sample line; an industrial cooling tower and its basin sit beyond a low wall at left. A compact text block anchored to the top-right carries the headline "Cooling towers", with "Cooling" picked out in cyan, and the subtitle "The application SEKO names for it".
Editorial composition of the SEKO Kontrol 800 controller beside a glass beaker holding three sensor probes, their cyan, magenta and green cables running to the enclosure's cable glands along the bottom edge; the lower terminal-cover panel is closed, with no interior visible. A compact text block anchored to the top-right carries the headline "Three inputs", with "Three" picked out in cyan, and the subtitle "pH · ORP · conductivity".
The SEKO Kontrol 800 controller wall-mounted on a plastered wall in an industrial water-treatment plant, LCD blank, beside two metering pumps on a stainless backplate cabled to probe fittings on a stainless process pipe below; beyond the low wall at left are a green horizontal centrifugal process pump, yellow chemical pipework and an open process basin. A compact text block anchored to the top-left carries the headline "Dosing loops", with "Dosing" picked out in cyan, and the subtitle "Cooling towers · boilers · RO · CIP".
Editorial composition over a photograph of the SEKO Kontrol 800's row of black cable glands along its lower edge, on a dark ground. A compact text block anchored to the top-left carries the headline "4 control outputs", with "4" picked out in cyan, and the subtitle "2 × 4–20 mA · 2 × frequency, 0–120 pulses/min".
Editorial composition of the SEKO Kontrol 800 wall-mounted above two chemical dosing pumps, wired via cable glands to two white chemical tanks with suction lances (each in a black drip tray) and to probe fittings on a section of grey PVC pipe, in a plant room with louvred windows showing greenery outside. A compact text block anchored to the top-left carries the headline "IP65 wall-mount", with "IP65" picked out in cyan, and the subtitle "ABS enclosure · 100–240 Vac".
Editorial composition of three glowing sensor probes (cyan, magenta, green) suspended above the SEKO Kontrol 800's lower enclosure, cables curving down to the row of black cable glands along the bottom edge; only the plain terminal-cover panel is visible, the display bezel is out of frame. A compact text block anchored to the top-left carries the headline "pH · ORP · µS", with "µS" picked out in cyan, and the subtitle "0–14 pH · ±2000 mV · 0.054–200,000 µS".